Multi-zone sizing needs a load calculation
19,000 BTU is sized across zones. Each zone needs its own load calculation.
ACCA Manual J ↗
19,000 BTU heat pumpAHRI reference 207657347
Check model number 3PAMSH18-MZO2 at your preferred retailer.

Photo of this model. Image details
What the published numbers mean before you compare every spec.
19,000 BTU is sized across zones. Each zone needs its own load calculation.
ACCA Manual J ↗At 5°F, certified output is 12,600 BTU/h — 66% of its 47°F rating.
ENERGY STAR ↗The cited fields do not confirm a pre-charged line set or DIY-line designation for this model.
Voltage is not published in the sources we cite, so confirm it before choosing equipment.
HSPF2 10.2 is above the 10.2 average among 125 models in the same rounded capacity class.
ENERGY STAR ↗A room-by-room load calculation supports this outdoor system across the planned zones.
You have not calculated each zone’s load.
Multi-zone systems need room-by-room load calculations and zone planning; use Manual J for final sizing.
| Outdoor model number | 3PAMSH18-MZO2 |
|---|---|
| AHRI reference number | 207657347 |
| Series | 3PAMS |
| Heating capacity at 47F | 19,000 BTU/h |
| Heating capacity at 17F | 14,400 BTU/h |
| Heating capacity at 5F | 12,600 BTU/h |
| SEER2 | 21 |
| EER2 | 12.5 |
| HSPF2 | 10.2 |
Values marked ENERGY STAR come from the certification dataset; values marked Manufacturer spec come from the linked product documents.
PerfectAire 3PAMSH18-MZO2 appears in the certification records under 3 separate certificate numbers. The equipment is the same; the tested pairing and the resulting ratings differ. This page carries them all.
| AHRI reference | Indoor unit | Heating at 47°F | Heating at 5°F | SEER2 | HSPF2 |
|---|---|---|---|---|---|
| 207657347 | Not supplied | 19,000 BTU/h | 12,600 BTU/h | 21 | 10.2 |
| 207657348 | Not supplied | 19,000 BTU/h | 13,300 BTU/h | 19 | 9.8 |
| 207657349 | Not supplied | 19,000 BTU/h | 12,900 BTU/h | 20 | 10 |
Every row comes from the same certification record set, retrieved 2026-08-09. Ask the seller which certificate number the unit you are quoted matches.
The sources we cite do not publish these values for this model, so we leave them blank rather than guess.
Room-size guidance is a starting point, not a load calculation. Confirm sizing and installation requirements with a qualified contractor.