SEER2
MRCOOL DIY-24-HP-C-230D25-O: 22.7. Pioneer YN024GLSI24RPG: 20. MRCOOL DIY-24-HP-C-230D25-O is certified 2.7 points higher.
MRCOOL DIY-24-HP-C-230D25-O vs Pioneer YN024GLSI24RPG
These two products come from different brands and share the same rounded certified heating-capacity class.
Both are 24k BTU-class heat pumps. Here is where they differ.
| Field | ||
|---|---|---|
| Brand | MRCOOL | Pioneer |
| Outdoor model | DIY-24-HP-C-230D25-O | YN024GLSI24RPG |
| Heating capacity at 47F | 24,000 BTU/h | 24,400 BTU/h |
| Heating capacity at 17F | 17,900 BTU/h | 22,000 BTU/h |
| Heating capacity at 5F | 16,100 BTU/h | 18,500 BTU/h |
| SEER2 | 22.7 | 20 |
| HSPF2 | 9.5 | 9.5 |
| Voltage | 208/230V | 208/230V |
| Certified flags | ENERGY STAR-certified | ENERGY STAR-certifiedccASHP-listed |
Check model number DIY-24-HP-C-230D25-O / DIY-24-HP-WMAH-230D25-O at your preferred retailer.
Check model number YN024GLSI24RPG / UT024GLSILCFHG at your preferred retailer.
All values come from official certification records; “not supplied” means the source does not publish that value. Open either model page for source links and retrieval dates.
A heat pump's headline capacity is measured at 47°F. What matters in January is how much of that output survives at 17°F and 5°F. The cold-climate specification exists because two systems with the same 47°F rating can behave very differently at design temperature.
| Certified heating output | MRCOOL DIY-24-HP-C-230D25-O | Pioneer YN024GLSI24RPG |
|---|---|---|
| At 47°F | 24,000 BTU/h | 24,400 BTU/h |
| At 17°F | 17,900 BTU/h | 22,000 BTU/h |
| At 5°F | 16,100 BTU/h | 18,500 BTU/h |
| Cold-climate listed | Not on the NEEP cold-climate list | Yes, on the NEEP cold-climate list |
MRCOOL DIY-24-HP-C-230D25-O holds 67% of its 47°F output at 5°F. That is less than the 83% average across the 70 certified models in the same size class.
Pioneer YN024GLSI24RPG holds 76% of its 47°F output at 5°F. That is less than the 83% average across the 70 certified models in the same size class.
Output figures come from the ENERGY STAR Certified Mini-Split Air Conditioners dataset; cold-climate listing comes from the NEEP cold-climate air-source heat pump product list. Retention percentages are calculated from those two published outputs.
MRCOOL DIY-24-HP-C-230D25-O: 22.7. Pioneer YN024GLSI24RPG: 20. MRCOOL DIY-24-HP-C-230D25-O is certified 2.7 points higher.
MRCOOL DIY-24-HP-C-230D25-O: 12.7. Pioneer YN024GLSI24RPG: 11.7. MRCOOL DIY-24-HP-C-230D25-O is certified 1 points higher.
MRCOOL DIY-24-HP-C-230D25-O: 9.5. Pioneer YN024GLSI24RPG: 9.5. The two are certified at the same figure.
MRCOOL DIY-24-HP-C-230D25-O sits above the 21.2 SEER2 average of the 70 certified models in its size class, and sits below the 10 HSPF2 average of the 70 certified models in its size class.
Pioneer YN024GLSI24RPG sits below the 21.2 SEER2 average of the 70 certified models in its size class, and sits below the 10 HSPF2 average of the 70 certified models in its size class.
SEER2, EER2, and HSPF2 come from the ENERGY STAR Certified Mini-Split Air Conditioners dataset. Size-class averages are calculated across every certified model in this catalog rounded to the same capacity class.
These decide whether a system is workable in a given house before efficiency matters at all. A model that needs a service you do not have is not a candidate.
| Requirement | MRCOOL DIY-24-HP-C-230D25-O | Pioneer YN024GLSI24RPG |
|---|---|---|
| Electrical service | 208/230V | 208/230V |
| Minimum circuit ampacity | 24 A | Not published in the certification records |
| Maximum breaker or fuse | 25 A | 25 A |
Electrical values are carried through from the certification records where the registries publish them. Confirm the final circuit requirement with a licensed electrician against the installation manual for the exact unit you buy.
Three public registries stand behind this page. Each one answers a different question, and none of them is a review site.
Certified heating and cooling output, SEER2, EER2, and HSPF2 for every mini-split that carries the ENERGY STAR mark.
ENERGY STAR Certified Mini-Split Air Conditioners dataset ↗Which systems meet the cold-climate specification, including the low-temperature output a system has to hold to qualify.
NEEP cold-climate air-source heat pump product list ↗The certificate that ties one outdoor unit to one indoor unit and fixes the ratings for that exact pairing.
AHRI Directory of Certified Product Performance ↗| Certification status | MRCOOL DIY-24-HP-C-230D25-O | Pioneer YN024GLSI24RPG |
|---|---|---|
| AHRI reference number | 216032547 | 217048767 |
| ENERGY STAR | Certified | Certified |
| NEEP cold-climate list | Not listed | Listed |
Records retrieved 2026-08-09. An AHRI certificate covers one outdoor unit paired with one indoor unit; a different indoor unit means a different certificate and different numbers.
Certified data settles output, efficiency, and cold-weather behaviour. It does not settle what a system costs to install in your house, how long the parts warranty runs, whether a local contractor will service the brand, or whether the unit fits the wall you had in mind. Those answers come from a quote and from the installation manual, not from a registry.
Capacity is a starting point, not a sizing decision. Two rooms with the same square footage can need different equipment once insulation, glazing, ceiling height, and climate zone are counted. Use a room-by-room load calculation before you buy either of these systems.
Check your room size