Certified spec comparison

ACIQ 10,000 BTU Ceiling Cassette vs MRCOOL 10,000 BTU Ceiling Cassette

ACIQ ACIQ-09ZPL-HP230C vs MRCOOL O-ES-09-HP-C-230C-O1

These two products come from different brands and share the same rounded certified heating-capacity class.

Every figure below is read from a certification record, not from a manufacturer marketing sheet. Where a registry publishes nothing, the row says so.

Why compare these models?

Both are 9k BTU-class heat pumps. Here is where they differ.

Certified field comparison

Field
ACIQ logoACIQ 10,000 BTU Ceiling CassetteModel #: ACIQ-09ZPL-HP230C / ACIQ-09CC-HH-MC
MRCOOL logoMRCOOL 10,000 BTU Ceiling CassetteModel #: O-ES-09-HP-C-230C-O1 / CASSETTE09HP-230C-O
BrandACIQMRCOOL
Outdoor modelACIQ-09ZPL-HP230CO-ES-09-HP-C-230C-O1
Heating capacity at 47F10,000 BTU/h10,000 BTU/h
Heating capacity at 17F9,700 BTU/h9,700 BTU/h
Heating capacity at 5F11,000 BTU/h11,000 BTU/h
SEER222.622.6
HSPF212.112.1
Voltage208/230V208/230V
Certified flags
ENERGY STAR-certifiedccASHP-listed
ENERGY STAR-certifiedccASHP-listed
Compare sellers

ACIQ 10,000 BTU Ceiling Cassette

Compare sellers

MRCOOL 10,000 BTU Ceiling Cassette

Check model number O-ES-09-HP-C-230C-O1 / CASSETTE09HP-230C-O at your preferred retailer.

All values come from official certification records; “not supplied” means the source does not publish that value. Open either model page for source links and retrieval dates.

Cold-weather output: what each system still delivers when it gets cold

A heat pump's headline capacity is measured at 47°F. What matters in January is how much of that output survives at 17°F and 5°F. The cold-climate specification exists because two systems with the same 47°F rating can behave very differently at design temperature.

Certified heating outputACIQ ACIQ-09ZPL-HP230CMRCOOL O-ES-09-HP-C-230C-O1
At 47°F10,000 BTU/h10,000 BTU/h
At 17°F9,700 BTU/h97% of its 47°F output9,700 BTU/h97% of its 47°F output
At 5°F11,000 BTU/h110% of its 47°F output11,000 BTU/h110% of its 47°F output
Cold-climate listedYes, on the NEEP cold-climate listYes, on the NEEP cold-climate list

ACIQ ACIQ-09ZPL-HP230C holds 110% of its 47°F output at 5°F. That is more than the 82% average across the 80 certified models in the same size class.

MRCOOL O-ES-09-HP-C-230C-O1 holds 110% of its 47°F output at 5°F. That is more than the 82% average across the 80 certified models in the same size class.

Output figures come from the ENERGY STAR Certified Mini-Split Air Conditioners dataset; cold-climate listing comes from the NEEP cold-climate air-source heat pump product list. Retention percentages are calculated from those two published outputs.

Efficiency, and what each rating actually measures

SEER2

Measures cooling efficiency over a season.

ACIQ ACIQ-09ZPL-HP230C: 22.6. MRCOOL O-ES-09-HP-C-230C-O1: 22.6. The two are certified at the same figure.

EER2

Measures cooling efficiency at one hot design condition.

ACIQ ACIQ-09ZPL-HP230C: 14. MRCOOL O-ES-09-HP-C-230C-O1: 14. The two are certified at the same figure.

HSPF2

Measures heating efficiency over a season.

ACIQ ACIQ-09ZPL-HP230C: 12.1. MRCOOL O-ES-09-HP-C-230C-O1: 12.1. The two are certified at the same figure.

ACIQ ACIQ-09ZPL-HP230C sits above the 21.9 SEER2 average of the 80 certified models in its size class, and sits above the 10.4 HSPF2 average of the 80 certified models in its size class.

MRCOOL O-ES-09-HP-C-230C-O1 sits above the 21.9 SEER2 average of the 80 certified models in its size class, and sits above the 10.4 HSPF2 average of the 80 certified models in its size class.

SEER2, EER2, and HSPF2 come from the ENERGY STAR Certified Mini-Split Air Conditioners dataset. Size-class averages are calculated across every certified model in this catalog rounded to the same capacity class.

Electrical and installation requirements

These decide whether a system is workable in a given house before efficiency matters at all. A model that needs a service you do not have is not a candidate.

RequirementACIQ ACIQ-09ZPL-HP230CMRCOOL O-ES-09-HP-C-230C-O1
Electrical service208/230V208/230V
Minimum circuit ampacityNot published in the certification records15 A
Maximum breaker or fuseNot published in the certification records15 A
Line set length range82 ftNot published in the certification records

Not published for either model: pre-charged line set, homeowner-install product line. Those figures live in the manufacturer's installation manual, which is the document to ask for.

Electrical values are carried through from the certification records where the registries publish them. Confirm the final circuit requirement with a licensed electrician against the installation manual for the exact unit you buy.

Where these numbers come from

Three public registries stand behind this page. Each one answers a different question, and none of them is a review site.

Certification statusACIQ ACIQ-09ZPL-HP230CMRCOOL O-ES-09-HP-C-230C-O1
AHRI reference number216032338217447802
ENERGY STARCertifiedCertified
NEEP cold-climate listListedListed

Records retrieved 2026-08-09. An AHRI certificate covers one outdoor unit paired with one indoor unit; a different indoor unit means a different certificate and different numbers.

What this comparison cannot tell you

Certified data settles output, efficiency, and cold-weather behaviour. It does not settle what a system costs to install in your house, how long the parts warranty runs, whether a local contractor will service the brand, or whether the unit fits the wall you had in mind. Those answers come from a quote and from the installation manual, not from a registry.

Capacity is a starting point, not a sizing decision. Two rooms with the same square footage can need different equipment once insulation, glazing, ceiling height, and climate zone are counted. Use a room-by-room load calculation before you buy either of these systems.

Check your room size